Home / Products / Vacuum Blood Collection Tube
Vacuum Blood Collection Tube
pro coagulation tube
Vacuum Blood Collection Tube Details

Item# TB040

The blood collection tubes allow ease-of-use and help to ensure a quality blood sample is collected.

Blood Collection Tubes Contains buffered 3.2% solution Sodium Citrate as anticoagulant. Available in 13 x 75 with 2.7 mL volume draw and 10.25 x.

The inner wall of the blood collection tube is ultrasonically cleaned and treated with a special process, which is close to the characteristics of the blood vessel wall of the human body, so that the platelet activity is in a moderate state, the blood coagulation process is smooth, the blood clot is normal, and the competitive adsorption process of the protein is fully suppressed, thereby providing sufficient for clinical testing Measure uncontaminated serum samples.

Collection and preservation of blood specimens for medical tests such as biochemistry, immunology, trace element detection, and various types of virus detection disposable medical and laboratory ware etc. High Quality. High Efficiency. Safe And Effective. High-Tech. Types: Trusted by Millions, Excellent Service, Welcome consult, High Cost-Effective, Reasonable price, Quality assurance.

1. Type of Blood Collection Tube

heparin tube

Heparin tube is used in blood collection and anticoagulation not only for routine clinical biochemistry tests and emergency biochemistry tests but also for some test items in blood rheology.

It is coated with heparin lithium or heparin sodium. the anticoagulant heparin activates antithrombins, thus blocking the coagulation cascade and producing a whole blood/ plasma sample instead of clotted blood plus serum. Soon after the sampling, turn the but 180 upside down, shaking and mixing 5-6 times.

heparin Anticoagulation Blood sample should be use within 6hrs after sampling, otherwise, the blood will coagulate again.

  • Color code: Green
  • Size: 2ml, 3ml, 4ml, 5ml, 6ml, 7ml
  • Specifications: 13x75mm, 13x100mm
  • Max Vacuum Tolerance: +/-10%

2. ESR Tube for Blood collection

esr tube

ESR tube is used in blood collection and anticoagulation for sedimentation rate test. It  contains a 3.8% buffered tri-sodium citrate solution (0.129 mol/l) with the mixing ratio of 1 port citrate solution to 4 parts blood. ESR measurement refers to the Westergren method. Sampleing the blood dosageas required to ensuring the test accuracy.

  • Color code: Black
  • Size:(3ml, 5ml, 7ml)
  • General Sampling Dosage: 1.6ml, 2.4ml
  • Max Vacuum Tolerance: <=5%

3. Glucose Tube for Blood Collection

glucose tube

Glucose Tube  is used in blood collection and anticoagulation for the analyses such as blood sugar,  sugar tolerance, antialkali haemoglobin and sugar water. It is available with different additives, dodium fluoride/potassium oxalate and sodium fluoride/ammonium fluoride/potassium oxalate. Now we use inhibitor for glucolysis.
Owing to the first use of special stabilizer and surface treatment inside the tube, glucoses tube successfully solves the unavoidable hemolysis and prevents the occurrence of insoluble and anti-coagulant substances.

  • Size:(2ml, 3ml, 4ml, 5ml)
  • Color code: Grey
  • Specification: 13x74mm, 13x100mm
  • Max Vacuum Tolerance: <=55

4. Plain Tube for Blood collection

plain tube

Plain tube is used in blood collection and storage for biochemistry, immunology and serology tests in medical inspection. It can provide enough and non-polluted serum specimen for clinical test, while keeping the serum invariable in the long inspection period.

  • Size: 2ml, 3ml, 4ml, 5ml, 6ml, 7ml
  • Color code: Red
  • Specification: 13x75mm, 13x100mm
  • Max Vacuum Tolerance: +/-10%

5. PT Tube for Blood collection

pt tube

PT Tube is used in blood collection and anticoagulation for sedimentation rate test. It  contains a 3.8% buffered tri-sodium citrate solution (0.129 mol/l) with the mixing ratio of 1 port citrate solution to 4 parts blood. ESR measurement refers to the Westergren method. Sampleing the blood dosageas required to ensuring the test accuracy.

  • Color code: Black
  • Size:(3ml, 5ml, 7ml)
  • General Sampling Dosage: 1.6ml, 2.4ml
  • Max Vacuum Tolerance: <=5%

6. Pro-coagulation tube for Blood collection

pro coagulation tube

Clot activator is precisely dispensed in the tube. This tube is used for blood collection and storage for biochemistry, immunology, element trace, various types of virus detection and so on for clinical tests. Invert 5-6 times after blood collection, and wait for 30 minutes before centrifuge.

7. EDTA tube for Blood Collection

edta tube

EDTA tubes are ideal for the examination of whole blood in haematology and are offered as either K2 EDTA or K3 EDTA tubes.

  • Colors of the closure system are compliant with ISO 6710 and EN 14820 standards for the identification of the tubes
  • Available Size: (3ml, 5ml, 7ml)
  • EDTA K2, EDTA K3 Blood Collecting Tube

8. ESR Tube for ESR Analyzer

Sodium citrate 3.8% is dispensed for sedimentation test. Blood and liquid additive volume ratio is 4:1. This tube is to match ESR Analyzer. This tube could not be used as the first tube to collect blood. Invert 8-10 times after blood collection. And the tube shall be inverted several times before experiment.

esr tube for esr analyzer
ClassificationItemsAdditiveColorTube MaterialMain Intended useTube size (mm)
Serum Tubeno additive tube/RedGlass/PETDeterminations
in serum for
clinical biochemistry,
immunology,
and serology
13×75/10016×100/125
Pro-coagulation tubeClot ActivatorGlass/PET
Gel & Color activator tubeGel & ActivatorGlass/Plastic
Plasma TubeGlucose TubePotassium Oxalate/Sodium fluoride or EDTA /sodium fluorideGlass/PlasticDeterminations
in stabilized
anti-coagulated
whole blood or
plasma for glucose
and lactate testing
13×17/100
PT Tube0.109mol/L Sodium Citrate
0.129mol/L Sodium Citrate (1:9)
Glass/PlasticDeterminations in cittrated plasma for coagulation testing13×75/100
Heparin Tubelithium Heparin
Sodium Heparin
Glass/PETDeterminations in heparinised plasma for clinical chemistry13×75/100
16×100
Whole Blood TubeEDTA TubeEDTA. K2
EDTA. K3
Glass/PETDeterminations in EDTA whole blood for hematology13×75/100
ESR Tube0.109mol/l Sodium Citrate (1:4)Glass/PlasticBlood Cell
sedimentation
rate test
13×75/100

Product Tags

Categories

Products Related

Item# SN300 The Luer adapter is used

Item# SN450 SAFETY MULTI-SAMPLE NEEDLE WITH

Item# SN211 SAFETY MULTI-SAMPLE NEEDLE VISIBLE

Item# SN441 SAFETY MULTI-SAMPLE NEEDLE VISIBLE.

Inquire Form