Patient Monitor | G6H

Patient Monitor | #G6H

Brief Introduction

FEATURES

●Displayer:8.4″ color TFT LCD screen with maximum 7waveform display
●Adjusting of lightness continuously make patient more comfortable in midnight

●Battery: Rechargeable high-energy built-in battery
●Advanced streamline outline design, portable, compact, lightweight
●Operating menu with multi-language interface selection: English, Spanish, Portuguese, Chinese,
French, Arabic, Russian, etc.
●Easy operation with user friendly menu structure design and rotary dial
●Against electrosurgical interference and defibrillation and no need to disconnect the monitor from
the patient in process of defibrillating.
●WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible
●Optional built-in wireless networking function
●Support external printer to record graph and trend
●Intelligent audio and visual comprehensive alarm

●Suitable for use in physicians’ offices, clinics, outpatient surgical centers, extended care facilities
and other patient care areas, which of require affordable monitoring
●Standard configuration: ECG, HR, PR, SpO2, ST analysis, RESP*2 (RA-LL impedance and nasal cavity),
NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation.

●Optional configuration: Wireless connection, Recorder and, 2-IBP

When the parameter value activated alarm, they will be shown in 3 different colors. (Red, Yellow and White)

Technical Parameter

●Temperature (surface and rectal)
●Measurement range: 25.0 – 45.0°C
●Accuracy: ± 0.1 °C
●Resolution: 0.1 °C
●Response time: ≤ 3 min

ECG
●Input: 5 wires ECG cable
●Lead section:Ⅰ,Ⅱ,Ⅲ/ aVR, aVL, aVF/ V

●Gain(mm/mV): 1/4, 1/2, 1, 2, 4
●Frequency response: Diagnosis  0.05 – 100Hz   Monitor 0.5 – 40 Hz   Surgery 1.0 – 25 Hz
●Sweep speed(mm/sec): 12.5, 25, 50
●Heart rate range: 30-254 BPM
●Heart rate accuracy: ± 1 %
●ST segment deviation analysis: -0.8-+0.8mV
●ST accuracy: ±0.02mv

●Respiration Rate(RA-LL impedance and nasal cavity)
●Measurement range: 0 – 120 BPM (adult)
●Accuracy: ± 1 BPM or 5 %
●Resolution: 1 BPM

●Environment Temperature: Operation 0.5 – 40°C, Storage -20 – 50 °C
●Relative humidity:≤ 80%

Pulse Rate
●SPO2 measurement range: 0 – 100 %
●Resolution: 1 %
●Pulse measurement range: 30- 254BPM
●Accuracy: ± 2 %
●Resolution: 1 BPM

NIBP (Non-invasive blood pressure)

●Measurement type : adult, pediatric, neonatal
●Measurement range: Systolic 4.0 – 37.0 kPa Diastolic  1.3 – 33.0 kPa Mean 2.6 – 35.0 kPa
●Accuracy : ± 0.4 kPa or 5 %
●Resolution: 0.1 kPa
●Protection: over pressure

IBP(Invasive blood pressure) (with venous punch) (Option)

●Measurement range: -1.3~40kPa (-10~300mmHg)
●Channel: 2 channel
●Transducer sensitivity: 5MV/V/mmHg
●Unit display: KPa or mmHg selectable

Power requirements

●Input:  98~260 V AC,  50/60Hz
●Consumption: ≤ 80VA

  • Country Origin: China

  • Brand Name: VIOMED or OEM

  • Certification: CE, ISO, FDA

  • Payment: TT or L/C