Vacuum Blood Collection Tube | #TB040
Brief Introduction
The blood collection tubes allow ease-of-use and help to ensure a quality blood sample is collected.
Blood Collection Tubes Contains buffered 3.2% solution Sodium Citrate as anticoagulant. Available in 13 x 75 with 2.7 mL volume draw and 10.25 x.
The inner wall of the blood collection tube is ultrasonically cleaned and treated with a special process, which is close to the characteristics of the blood vessel wall of the human body, so that the platelet activity is in a moderate state, the blood coagulation process is smooth, the blood clot is normal, and the competitive adsorption process of the protein is fully suppressed, thereby providing sufficient for clinical testing Measure uncontaminated serum samples.
Collection and preservation of blood specimens for medical tests such as biochemistry, immunology, trace element detection, and various types of virus detection disposable medical and laboratory ware etc. High Quality. High Efficiency. Safe And Effective. High-Tech. Types: Trusted by Millions, Excellent Service, Welcome consult, High Cost-Effective, Reasonable price, Quality assurance.
Types of Blood Collection Tube
1. Heparin Tube for Blood Collection
Heparin tube is used in blood collection and anticoagulation not only for routine clinical biochemistry tests and emergency biochemistry tests but also for some test items in blood rheology.
It is coated with heparin lithium or heparin sodium. the anticoagulant heparin activates antithrombins, thus blocking the coagulation cascade and producing a whole blood/ plasma sample instead of clotted blood plus serum. Soon after the sampling, turn the but 180 upside down, shaking and mixing 5-6 times.
heparin Anticoagulation Blood sample should be use within 6hrs after sampling, otherwise, the blood will coagulate again.
- Color code: Green
- Size: 2ml, 3ml, 4ml, 5ml, 6ml, 7ml
- Specifications: 13x75mm, 13x100mm
- Max Vacuum Tolerance: +/-10%
2. ESR Tube for blood collection
ESR tube is used in blood collection and anticoagulation for sedimentation rate test. It contains a 3.8% buffered tri-sodium citrate solution (0.129 mol/l) with the mixing ratio of 1 port citrate solution to 4 parts blood. ESR measurement refers to the Westergren method. Sampleing the blood dosageas required to ensuring the test accuracy.
Color code: Black
Size:(3ml, 5ml, 7ml)
General Sampling Dosage: 1.6ml, 2.4ml
Max Vacuum Tolerance: <=5%
3. Glucose Tube for blood collection
Glucose Tube is used in blood collection and anticoagulation for the analyses such as blood sugar, sugar tolerance, antialkali haemoglobin and sugar water. It is available with different additives, dodium fluoride/potassium oxalate and sodium fluoride/ammonium fluoride/potassium oxalate. Now we use inhibitor for glucolysis.
Owing to the first use of special stabilizer and surface treatment inside the tube, glucoses tube successfully solves the unavoidable hemolysis and prevents the occurrence of insoluble and anti-coagulant substances.
Size:(2ml, 3ml, 4ml, 5ml)
Color code: Grey
Specification: 13x74mm, 13x100mm
Max Vacuum Tolerance: <=55
4. Plain Tube for blood collection
Plain tube is used in blood collection and storage for biochemistry, immunology and serology tests in medical inspection. It can provide enough and non-polluted serum specimen for clinical test, while keeping the serum invariable in the long inspection period.
Size: 2ml, 3ml, 4ml, 5ml, 6ml, 7ml
Color code: Red
Specification: 13x75mm, 13x100mm
Max Vacuum Tolerance: +/-10%
5. PT Tube for blood collection
PT Tube is used in blood collection and anticoagulation for sedimentation rate test. It contains a 3.8% buffered tri-sodium citrate solution (0.129 mol/l) with the mixing ratio of 1 port citrate solution to 4 parts blood. ESR measurement refers to the Westergren method. Sampleing the blood dosageas required to ensuring the test accuracy.
Color code: Black
Size:(3ml, 5ml, 7ml)
General Sampling Dosage: 1.6ml, 2.4ml
Max Vacuum Tolerance: <=5%
6. SERUM Tube for blood collection
7. EDTA Tube for blood collection
EDTA tubes are ideal for the examination of whole blood in haematology and are offered as either K2 EDTA or K3 EDTA tubes.
- Colors of the closure system are compliant with ISO 6710 and EN 14820 standards for the identification of the tubes
- Available Size: (3ml, 5ml, 7ml)
- EDTA K2, EDTA K3 Blood Collecting Tube
SPECIFICATION
Classification | Items | Additive | Color | Tube Material | Main Intended use | Tube size (mm) |
---|---|---|---|---|---|---|
Serum Tube | no additive tube | / | Red | Glass/PET | Determinations in serum for clinical biochemistry, immunology, and serology | 13×75/100 16×100/125 |
Pro-coagulation tube | Clot Activator | Glass/PET | ||||
Gel & Color activator tube | Gel & Activator | Glass/Plastic | ||||
Plasma Tube | Glucose Tube | Potassium Oxalate/ Sodium fluoride or EDTA / sodium fluoride | Glass/Plastic | Determinations in stabilized anti-coagulated whole blood or plasma for glucose and lactate testing | 13×17/100 | |
PT Tube | 0.109mol/L Sodium Citrate 0.129mol/L Sodium Citrate (1:9) | Glass/Plastic | Determinations in cittrated plasma for coagulation testing | 13×75/100 | ||
Heparin Tube | lithium Heparin Sodium Heparin | Glass/PET | Determinations in heparinised plasma for clinical chemistry | 13×75/100 16×100 | ||
Whole Blood Tube | EDTA Tube | EDTA. K2 EDTA. K3 | Glass/PET | Determinations in EDTA whole blood for hematology | 13×75/100 | |
ESR Tube | 0.109mol/l Sodium Citrate (1:4) | Glass/Plastic | Blood Cell sedimentation rate test | 13×75/100 |